Soloon Controls (Beijing) Co., Ltd. +86-10-67886688
soloon-logo
soloon-logo
Contact Us
S6025 Fluid Level Switch

S6061-08/16 Modulating Rapid Running Damper Actuator

S6061-08/16Nm Modulating Type Rapid Running Damper Actuator is specially designed for small air damper and terminal control unit of air volume air system. Due to the small size and control flexibly, also usually used in space where is limited.

S6061-08/16 Modulating Rapid Running Damper Actuator

Features of S6061-08/16 Modulating Rapid Running Damper Actuator

 

  • With 2 auxiliary switches are optional
  • Torque 08/16NM
  • Power supply AC/DC 24V or AC 230V
  • Modulating

 

Outline and Mounting Dimension of S6061-08/16 Modulating Rapid Running Damper Actuator

 

s6016-08-16-modulating-rapid-running-damper-actuator-1

 

Technical Datasheet of S6061-08/16 Modulating Rapid Running Damper Actuator

 

Item Unit S6061-08

AFK

S6061-16

AFK

S6061-08ANK S6061-16ANK
Torque Nm 8 16 8 16
Damper area m2 2 4 2 4
Running time sec 8 16 8 16
Power supply V 24VAC/DV
Frequency Hz 50/60

7.5W 50/60Hz

Running consumption W 8.5W
Maintaining consumption W 0.7W
Weight Kg 1.Kg
Control signal 0(4)…20mA   0(2)…10V
Rotation angle 0~90º(Max 93°)
Limited angle 5~85º(Per step 5º)
Auxiliary switch rating 3(1.5)Amp 250V
Life cycle >70000 cycles
Noise level 45dB(A)
Electrical level
Protection level IP44 or IP54
Ambient Temperature -20~+50℃
Ambient Humidity 5~95%RH
Storage temperature -40~+70℃
Certificate CE   UL(Except 230V)

Remark: After lead out the Actuator wire by PG joint, the IP Protection can reach IP54.

 

Angle of Rotation Limiting of S6061-08/16 Modulating Rapid Running Damper Actuator

 

The rotation angle or working range of the actuator can be adjusted 5°by adapter so that can limit mechanically. You just press the locking clip to lose the adapter.

 

Wiring diagram of S6061-08/16 Modulating Rapid Running Damper Actuator

 

S6061-08/16AK Damper Actuator can operate by 0(4)…20mA and 0(2)…10V

Main/subsidiary control of S6061-08/16 Modulating Rapid Running Damper Actuator

 

s6016-08-16-modulating-rapid-running-damper-actuator-4

 

 

Control Signal and Choose the Rotate direction of S6061-08/16 Modulating Rapid Running Damper Actuator

 

s6016-08-16-modulating-rapid-running-damper-actuator-5

 

The electronic controller of VR1 and VR2 can set the scope of control signals discretionally. VR1 is used for setting high-grade signals. And VR2 is used for setting low-grade signals. The leaving factory setting positions are matched with the control signal of 0…20mA, 0…10V.

 

Setting the angle of direction of S6061-08/16 Modulating Rapid Running Damper Actuator

 

Must make the contact pin(C) is as Same direction as motor plug.

 

Factory setting of S6061-08/16 Modulating Rapid Running Damper Actuator

 

s6016-08-16-modulating-rapid-running-damper-actuator-6

 

Switch at 10° – Switch b at 80°

The switching position can be manually changed to any required position by turning the ratchet.

 

Auxiliary Switch specification of S6061-08/16 Modulating Rapid Running Damper Actuator

 

There are two auxiliary switches of S6061-08/16AFK damper actuator, can set the angle 0-90° (factory sets 10° and 80°), it will show a signal when the actuator turns to the setting angle.

 

What is HVAC Air Duct Damper Actuator?

The Function of HVAC Air Duct Damper Actuator


Contact Us Product Inquiry
Contact Us
If you are interested in our products.
Please fill in the form & Contact Us.
+86-10-67886688